Accoustical Rating
Sound Transmission Class rating of 33 (S.T.C. - 33). Tested by Riverbank Laboratories.
Connectors
Hardened steel Mod-EZ specialized pin and clip system. Laminated hardwood connecting post. 2" x 2" x panel height.
Leveling Guides
1 1/2" threaded steel stem on cushion foot. Two per panel - three per panel on radius.
Support Foot
3/16" high grade steel base, 1/8" welded uprights. Scuff-resistant, textured powder coat finish.
Wall Bracket
16 gauge cold rolled steel. Scuff resistant
Fabrics
Grade I - 100% Olefin (ends-24) (picks-26) 8.8 oz. per lineal yard
Grade II - 100% Polyester (ends-17) (picks-16) 16 oz. per lineal yard
Raceway
Aluminum attachment footings with impact resistant extruded plastic cover
Electrical
High capacity eight wire, four circuit 120VAC system rated at 20A. Receptacles rated at 15A.
Panels and hardware pass all ETL standards as prescribed under UL-1286 codes.